State, Not Scar · claim VASO-C182 · Observation rung · The phenomenon at the fingertip

On sonoelastography, active sites had larger trigger point areas (mean ± SD, 0.57 ± 0.20 cm²) than latent sites (0.36 ± 0.16 cm²).

Stiff regions are larger at points painful on their own than at points painful only when pressed.

AI-extractedorigin: split of VASO-C033 (report 2026-09-09-report-vasocomputation-023157); anchored by the splitter in the same text

credibility — is the claim itself true?

Provisionally supported

Mean stiff areas of 0.57 cm² at active and 0.36 cm² at latent sites on blinded vibration sonoelastography (VASO-E087, VASO-E089, VASO-E104). The calf parallel and further listings are context (VASO-E085, VASO-E093, VASO-E106). One laboratory, one vibration frequency, palpation-selected sites.

diagnosticity — how much does it decide the thesis?

low

A graded stiffness ordering that all accounts can accommodate.

Evidence

Supports (3)

Supports· moderateVASO-E087

Ballyns 2011: vibration sonoelastography stiff-area measurements separate active, latent and normal sites — part 1.1

what the source states
On sonoelastography, active sites (spontaneously painful with palpable myofascial trigger points) had larger trigger points, with a mean ± SD area of 0.57 ± 0.20 cm², as stated: "active sites (spontaneously painful with palpable myofascial trigger points) had larger trigger points".
what we infer
Direct instrumented support for the stiffness component of VASO-C005 and for the graded active/latent/normal ordering. Sonographers were blinded to clinical status, which is stronger than the palpation-only literature. It says nothing about what the stiff tissue is (contracted fibre, guarding, fascial change, or vascular).
limitations
  • Single vibration frequency from an off-the-shelf massager; the authors note frequency-independence was not confirmed and shear elasticity was not measured.
  • Sites were selected by palpation, so the measured contrast presupposes the palpated classification.
  • Same NIH lineage as SRC-SHAH-2008; not an independent group.
  • Relinked at the answer's re-reading 2026-09-20 (2026-09-20-answer-vasocomputation-172213): VASO-C033 was split into VASO-C182, VASO-C183, VASO-C184; this record now cites the parts, and which of them it bears on is for a later reading
  • Second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-reverify-vasocomputation-190441, verify-v6) found the passage bears on VASO-C005, VASO-C182, VASO-C184 and not on VASO-C183; the link dropped at intake: The quoted phrase and the 0.57\u00b10.20 cm\u00b2 active-site value are accurately drawn from the Results/Abstract and are at the stated locator, and the statement is a fair, non-inflated account of that value, so it supports the general difference claim (C005) and, since the active value matches exactly what is needed for the active-vs-latent comparison, also bears on C182 and C184. But it says nothing about the normal-site value (0.17\u00b10.22) needed to support C183's active-and-latent-vs-normal comparison, so that claim is not borne on by this passage. Independence is properly flagged in the limitations, and the record is a single atomic proposition.
Jeffrey J. Ballyns (2011)AI-verified citation
Supports· moderateVASO-E089

Ballyns 2011: vibration sonoelastography stiff-area measurements separate active, latent and normal sites — part 1.2 — toward VASO-C182

what the source states
Latent sites (palpable trigger points painful on palpation) had a mean trigger point area of 0.36 ± 0.16 cm², as stated: "latent sites (palpable trigger points painful on palpation; 0.36 ± 0.16 cm²)".
what we infer
Direct instrumented support for the stiffness component of VASO-C005 and for the graded active/latent/normal ordering. Sonographers were blinded to clinical status, which is stronger than the palpation-only literature. It says nothing about what the stiff tissue is (contracted fibre, guarding, fascial change, or vascular).
limitations
  • Single vibration frequency from an off-the-shelf massager; the authors note frequency-independence was not confirmed and shear elasticity was not measured.
  • Sites were selected by palpation, so the measured contrast presupposes the palpated classification.
  • Same NIH lineage as SRC-SHAH-2008; not an independent group.
  • Relinked at the answer's re-reading 2026-09-20 (2026-09-20-answer-vasocomputation-172213): VASO-C033 was split into VASO-C182, VASO-C183, VASO-C184; this record now cites the parts, and which of them it bears on is for a later reading
  • Second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-reverify-vasocomputation-190441, verify-v6) found the passage bears in different directions on the claims the record named; this record carries "supports" toward VASO-C182, the rest went to a record of its own at intake: The quote and locator are accurate and the record fairly reports the latent-site mean area (0.36 ± 0.16 cm²). This number directly matches and supports VASO-C182 (which states both means), but the record contains no normal-site value or significance test, so it does not itself bear on VASO-C183's normal-comparison claim or on VASO-C184's active-vs-latent significance claim. It only generally bears on VASO-C005's broad claim of measurable differences, so that is context rather than direct support. Independence is properly noted given shared NIH lineage.
Jeffrey J. Ballyns (2011)AI-verified citation
Supports· moderateVASO-E104

Ballyns 2011: vibration sonoelastography stiff-area measurements separate active, latent and normal sites — part 3 — toward VASO-C182, VASO-C183, VASO-C184 — part 1

what the source states
Receiver operating characteristic analysis showed that trigger point "area measurements could robustly distinguish between active, latent, and normal sites".
what we infer
Direct instrumented support for the stiffness component of VASO-C005 and for the graded active/latent/normal ordering. Sonographers were blinded to clinical status, which is stronger than the palpation-only literature. It says nothing about what the stiff tissue is (contracted fibre, guarding, fascial change, or vascular).
limitations
  • Single vibration frequency from an off-the-shelf massager; the authors note frequency-independence was not confirmed and shear elasticity was not measured.
  • Sites were selected by palpation, so the measured contrast presupposes the palpated classification.
  • Same NIH lineage as SRC-SHAH-2008; not an independent group.
  • Relinked at the answer's re-reading 2026-09-20 (2026-09-20-answer-vasocomputation-172213): VASO-C033 was split into VASO-C182, VASO-C183, VASO-C184; this record now cites the parts, and which of them it bears on is for a later reading
  • Second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-reverify-vasocomputation-190441, verify-v6) found the passage bears in different directions on the claims the record named; this record carries "context" toward VASO-C182, VASO-C183, VASO-C184, the rest went to a record of its own at intake: The quoted sentence and AUC figures are accurately reported and correctly located in the Results/Abstract, and the source does not repeat another lab's independent dataset (correctly flagged as NIH-lineage overlap). However, the sourceStatement only reports the ROC/AUC classification finding, not the specific mean-area comparisons that VASO-C182, VASO-C183, and VASO-C184 assert; it therefore bears on the topic without directly establishing those specific quantitative claims, so it is better read as context for them, while it does support the broader claim (VASO-C005) that active sites differ measurably in stiffness/area from other tissue.
  • Direction set to "supports" (from "context") by the second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-answer-vasocomputation-192504, verify-v6) at intake: The quoted ROC/AUC 'robustly distinguish' finding sits in the same Results paragraph and rests on the same underlying area data as the specific mean-difference claims (active>latent>normal, each P<.01); a strong ROC/AUC separation between groups is itself evidence that the group means differ as the claims state, not merely background context. The quote is accurately located and rendered, the NIH lineage overlap is properly disclosed, and the statement is a single atomic proposition, but labeling it 'context' understates its evidentiary bearing on these three specific quantitative claims — it should be read as supporting evidence for each.
  • Second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-answer-vasocomputation-192504, verify-v6) disputes the stated direction toward VASO-C186: The quoted ROC/AUC 'robustly distinguish' passage is accurately quoted and correctly located in the Results/Abstract, and the NIH-lineage overlap is properly disclosed. But VASO-C186 asserts a distinct finding — that elastography-measured trigger point areas showed trends similar to pain pressure threshold scores — which is a separate sentence/observation in the same paragraph, not established or restated by the ROC/AUC discriminability statement quoted here. The classification-strength quote does not speak to whether the area trend paralleled the PPT trend, so it does not bear on this specific claim even though it comes from the same study and topic area.
  • Second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-answer-vasocomputation-192504, verify-v6) disputes the stated direction toward VASO-C187: The quoted ROC/AUC 'robustly distinguish' finding is accurately reported and correctly located, and NIH lineage overlap is properly disclosed, but it says nothing about the specific mean ± SD area value (0.17 ± 0.22 cm²) for normal sites that VASO-C187 asserts. A classification-strength statistic does not itself establish a particular descriptive mean, so the passage bears only as context on this specific quantitative claim rather than as direct support.
  • Corrected by the operator on 2026-09-20 (session_01AiXD4y5Y91KC7iM3uBhWmu, operator-by-hand-v1): relinked from VASO-C182, VASO-C185, VASO-C186, VASO-C187, VASO-C184 to VASO-C182, VASO-C187, VASO-C184, VASO-C188, VASO-C189 — its statement — area measurements distinguish active, latent and normal sites — bears on both comparisons against normal tissue; the bearing is read from the record's own statement, not from the reader, and stands for the panel's judgment
Jeffrey J. Ballyns (2011)AI-verified citation

Context (3)

Context· weakVASO-E085

Landfald 2025: active/latent differences in a second muscle as context for the graded-stiffness and fresh/old claims — part 2

what the source states
Active gastrocnemius MTrPs had a "larger cross-sectional area (28 mm² vs. 17 mm², p = 0.014)" than latent points; Table 2 gives 28 ± 6 against 17 ± 5 mm².
what we infer
Size by clinical class in a second muscle; the same parallel, carrying no weight for or against the fresh/old claims.
limitations
  • Different muscle, method and site classes from the trapezius sonoelastography study.
  • Active/latent is not the fresh/old axis; the authors' 'earlier or less fibrotic' reading is their conjecture.
  • Second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-verify-vasocomputation-113521, verify-v6) found the passage bears on VASO-C033 and not on VASO-C075, VASO-C076; the links dropped at intake: The quoted active-vs-latent comparison (VAS, cross-sectional area, stiffness ratio) is accurately drawn from Table 2/Discussion and is genuinely a different-muscle analogue that can serve as context for the trapezius active/latent claim C033. But the quoted statement says nothing about session counts, duration, or knot age/freshness, so it does not bear at all on the fresh-knot (C075) or ancient-knot (C076) claims about time-to-release, despite the record listing 'context' for all three.
  • One clause of a three-part comparison the source reports in one sentence and one table; the sibling parts carry the other two.
Ingrid C. Landfald (2025)AI-verified citation
Context· moderateVASO-E093

Ballyns 2011: vibration sonoelastography stiff-area measurements separate active, latent and normal sites — part 2.2 — toward VASO-C182

what the source states
By vibration elastography, "active sites were significantly larger than latent sites" (P < .01).
what we infer
Direct instrumented support for the stiffness component of VASO-C005 and for the graded active/latent/normal ordering. Sonographers were blinded to clinical status, which is stronger than the palpation-only literature. It says nothing about what the stiff tissue is (contracted fibre, guarding, fascial change, or vascular).
limitations
  • Single vibration frequency from an off-the-shelf massager; the authors note frequency-independence was not confirmed and shear elasticity was not measured.
  • Sites were selected by palpation, so the measured contrast presupposes the palpated classification.
  • Same NIH lineage as SRC-SHAH-2008; not an independent group.
  • Relinked at the answer's re-reading 2026-09-20 (2026-09-20-answer-vasocomputation-172213): VASO-C033 was split into VASO-C182, VASO-C183, VASO-C184; this record now cites the parts, and which of them it bears on is for a later reading
  • Second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-reverify-vasocomputation-190441, verify-v6) found the passage bears in different directions on the claims the record named; this record carries "context" toward VASO-C182, the rest went to a record of its own at intake: The quoted sentence accurately reports the active-versus-latent size comparison (P<.01) from the Results section, and its statement is a fair, narrow account of that specific finding. It directly supports VASO-C184 (active > latent) and generally supports VASO-C005's broader claim about stiffness differences, but it says nothing about the specific magnitude values in C182 (0.57 vs 0.36 cm²) or about the active/latent-versus-normal comparison in C183, so it only bears as context on C182 and not at all on C183.
Jeffrey J. Ballyns (2011)AI-verified citation
Context· moderateVASO-E106

Ballyns 2011: vibration sonoelastography stiff-area measurements separate active, latent and normal sites — part 3 — toward VASO-C182, VASO-C183, VASO-C184 — part 2.3

what the source states
Trigger point area measurements from ROC analysis yielded an area under the curve of "0.8 for latent versus normal, respectively" for latent versus normal sites.
what we infer
Direct instrumented support for the stiffness component of VASO-C005 and for the graded active/latent/normal ordering. Sonographers were blinded to clinical status, which is stronger than the palpation-only literature. It says nothing about what the stiff tissue is (contracted fibre, guarding, fascial change, or vascular).
limitations
  • Single vibration frequency from an off-the-shelf massager; the authors note frequency-independence was not confirmed and shear elasticity was not measured.
  • Sites were selected by palpation, so the measured contrast presupposes the palpated classification.
  • Same NIH lineage as SRC-SHAH-2008; not an independent group.
  • Relinked at the answer's re-reading 2026-09-20 (2026-09-20-answer-vasocomputation-172213): VASO-C033 was split into VASO-C182, VASO-C183, VASO-C184; this record now cites the parts, and which of them it bears on is for a later reading
  • Second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-reverify-vasocomputation-190441, verify-v6) found the passage bears in different directions on the claims the record named; this record carries "context" toward VASO-C182, VASO-C183, VASO-C184, the rest went to a record of its own at intake: The quoted sentence and AUC figures are accurately reported and correctly located in the Results/Abstract, and the source does not repeat another lab's independent dataset (correctly flagged as NIH-lineage overlap). However, the sourceStatement only reports the ROC/AUC classification finding, not the specific mean-area comparisons that VASO-C182, VASO-C183, and VASO-C184 assert; it therefore bears on the topic without directly establishing those specific quantitative claims, so it is better read as context for them, while it does support the broader claim (VASO-C005) that active sites differ measurably in stiffness/area from other tissue.
  • Second reader (claude-sonnet-5, 2026-09-20, run 2026-09-20-answer-vasocomputation-192504, verify-v6) found the passage bears in different directions on the claims the record named; this record carries "context" toward VASO-C182, VASO-C184, the rest went to a record of its own at intake: The quoted AUC figure (0.8 for latent versus normal) is verbatim from the abstract and correctly located; it is a single, atomic statistical claim and the record properly flags NIH-lineage overlap. However, this ROC/AUC statistic on latent-versus-normal classification directly evidences the latent-vs-normal size difference asserted in VASO-C183, so it should be scored as supporting that claim rather than merely 'context'; it remains context for VASO-C182 (active-vs-latent means) and VASO-C184 (active-vs-latent significance), which it does not address.
Jeffrey J. Ballyns (2011)AI-verified citation

strongest unresolved objection

The site classes are defined by the same palpation whose reliability is disputed.

what would change our mind

  • Independent replication with instrument-defined sites.
  • The gradient disappearing under blinded site selection.

parent claims

Assessment history

Append-only AI overlay records; the canon claim file is never mutated.

Unresolvedconfidence: low · claude-fable-5-1 · run 2026-09-20-edition-174151 · unreviewed draft

Held on its Ballyns 2011 anchor: the record drawn from the paper's stiff-area figures is provisional pending re-reading after the compound claim it cited was refused and split, and carries no weight. The only admitted record attached is VASO-E085 (context, weak), the calf cross-sectional-area difference between active and latent points in a different muscle by a different method, which is a parallel and not a measurement of trapezius sonoelastography.

Provisionally supportedconfidence: moderate · claude-fable-5-1 · run 2026-09-20-edition-191842 · unreviewed draft

The paper's own results report the figures (VASO-E087 gives the active 0.57 ± 0.20 cm²; VASO-E089 the latent 0.36 ± 0.16 cm²), with the active-over-latent significance and ROC separation as context (VASO-E093, VASO-E095). Sonographers were blinded to clinical status. One laboratory, one vibration frequency from an off-the-shelf massager, sites selected by palpation, same NIH lineage as the biochemistry; the calf active/latent area difference (VASO-E085) is context from another muscle and method, not a replication.

Provisionally supportedconfidence: moderate · claude-fable-5-1 · run 2026-09-20-edition-194053 · unreviewed draft

Both means are quoted from the paper's results (VASO-E087 for the active value, VASO-E089 for the latent value), with the active-versus-latent significance and classifier (VASO-E093, VASO-E106) as context and the calf area difference (VASO-E085) as a parallel from another muscle and method. Blinded sonographers, one laboratory, one vibration frequency, palpation-selected sites.

Provisionally supportedconfidence: moderate · claude-fable-5-1 · run 2026-09-21-edition-013849 · unreviewed draft

Ballyns 2011 reports mean areas of 0.57 ± 0.20 cm² at active and 0.36 ± 0.16 cm² at latent sites on vibration sonoelastography (VASO-E087, VASO-E089), with the active-versus-latent significance and ROC separation as context (VASO-E093, VASO-E106) and the calf active/latent size difference as a parallel from another muscle and method (VASO-E085). Blinded sonographers, one laboratory, one vibration frequency, palpation-selected sites, same NIH lineage as the biochemistry.

Provisionally supportedconfidence: moderate · claude-fable-5-1 · run 2026-09-22-edition-123015 · unreviewed draft

The abstract's means — 0.57 ± 0.20 cm² at active and 0.36 ± 0.16 cm² at latent sites — are recorded directly (VASO-E087, VASO-E089), with the ROC statement that area distinguishes the site classes (VASO-E104); the active-versus-latent significance (VASO-E093), the latent-versus-normal classifier (VASO-E106) and the calf parallel (VASO-E085) enter as context. Blinded sonographers, but one laboratory, one vibration frequency from an off-the-shelf massager, palpation-selected sites and the same NIH lineage as the biochemistry.

Provisionally supportedconfidence: moderate · claude-fable-5-1 · run 2026-09-23-edition-015207 · unreviewed draft

Ballyns 2011 states the two means directly (VASO-E087 for the active value, VASO-E089 for the latent value) and the ROC analysis distinguishes the classes (VASO-E104); the active-versus-latent significance statement (VASO-E093), the latent-versus-normal classifier (VASO-E106) and the calf parallel from Landfald 2025 (VASO-E085) are context. One laboratory, one vibration frequency from an off-the-shelf massager, palpation-selected sites, blinded sonographers.

Establishedconfidence: high · Gemini 3.8 Flash (Google) — independent check run via gemini-3.8-flash · run 2026-09-30-check-gemini-104542 · unreviewed draft

The descriptive finding that active trigger points had significantly larger stiff areas on vibration sonoelastography (0.57 ± 0.20 cm²) than latent sites (0.36 ± 0.16 cm²) is verified directly against the published results of Ballyns et al. 2011 (VASO-E087, VASO-E089, VASO-E104), and corroborated in another muscle by Landfald 2025 (VASO-E085). The strongest opposing consideration is that the underlying classification of sites as active or latent relied on subjective manual palpation prior to imaging.

Provisionally supportedconfidence: moderate · GLM 5.3 Flash (Z.ai, via Venice) — independent check run via z-ai-glm-5-3-flash · run 2026-09-30-check-glm-104542 · unreviewed draft

The active and latent area values are directly anchored with blinded sonographers (E087, E089), corroborated by an AUC of 0.8 for active versus latent classification (E099) and by a second laboratory finding the same direction in gastrocnemius (E085, weak context). The strongest opposing considerations are the single vibration frequency used, sites selected by an unblinded palpating examiner so the contrast presupposes the classification, and shared NIH lineage across both supporting studies.

Establishedconfidence: high · GPT-5.6 Sol (OpenAI) — independent check run via gpt-5.6-sol · run 2026-09-30-check-gpt-104542 · unreviewed draft

VASO-E087 and VASO-E089 directly provide the active- and latent-site means, while VASO-E092 reports that active sites were significantly larger than latent sites. VASO-E085 gives a qualitatively similar active-greater-than-latent size pattern in a different muscle and method, although it is only contextual. The strongest opposing consideration is that the exact result comes from one palpation-selected cohort and one imaging lineage rather than an independent replication of the numerical estimates.

Well supportedconfidence: moderate · Grok 4.5 (xAI) — independent check run via grok-4.5 · run 2026-09-30-check-grok-104542 · unreviewed draft

Ballyns abstract/results state active-site mean stiff area 0.57 ± 0.20 cm² versus latent 0.36 ± 0.16 cm² (E087, E089). Sonographers blinded to clinical status. Strongest opposing consideration is palpation-preselected sites and single-frequency vibration method without confirmed shear elasticity.

Well supportedconfidence: high · Opus 5.5 (Anthropic) — independent check run via claude-opus-5-5 · run 2026-09-30-check-opus-104542 · unreviewed draft

The values are quoted verbatim from the Ballyns 2011 abstract (E087, E089). The active–latent difference was significant (P < .01; E092, E093), area was a fair classifier of active versus latent sites (E099), and sonographers were blinded to clinical status. An independent group using another muscle and elastography method found the same direction: active points had larger cross-sectional areas than latent ones (28 vs 17 mm²; E085). One discrepancy should be resolved before the classifier figures are cited: the abstract assigns AUC 0.9 to active versus latent (E101), while the Results assign 0.9 to active versus normal and 0.8 to active versus latent (E096, E099); the ordering claimed here does not depend on which is right. Strongest opposing consideration: sites were chosen and classed by palpation, the vibration source was a single-frequency massager with frequency-independence unconfirmed, and the group shares the NIH lineage of the other Ballyns and Shah records. The specific values are tied to this method and study, even though the ordering is robust.

Provisionally supportedconfidence: moderate · claude-opus-5-5 · run 2026-09-30-edition-072251 · unreviewed draft

Mean stiff areas of 0.57 cm² at active and 0.36 cm² at latent sites on blinded vibration sonoelastography (VASO-E087, VASO-E089, VASO-E104). The calf parallel and further listings are context (VASO-E085, VASO-E093, VASO-E106). One laboratory, one vibration frequency, palpation-selected sites.