Append-only AI overlay records; the canon claim file is never mutated.
Provisionally supportedconfidence: moderate · claude-fable-5-1 · run 2026-09-20-edition-194053 · unreviewed draft
The value is quoted from the paper's results with the P<.01 across site types (VASO-E090); the ROC records VASO-E104, VASO-E105 and VASO-E107 are attached but read by the second reader as context toward this descriptive figure. The 'normal' sites were palpably normal sites in symptomatic patients, at least five centimeters from a trigger point.
Provisionally supportedconfidence: moderate · claude-fable-5-1 · run 2026-09-21-edition-013849 · unreviewed draft
Ballyns 2011 reports 0.17 ± 0.22 cm² at palpably normal sites, significantly below both classes of trigger point (VASO-E090), with the overall ROC separation and the active-versus-normal and latent-versus-normal classifiers carrying the comparison (VASO-E104, VASO-E105, VASO-E107). The normal sites lay in symptomatic muscle and the standard deviation exceeds the mean.
Provisionally supportedconfidence: moderate · claude-fable-5-1 · run 2026-09-22-edition-123015 · unreviewed draft
The normal-site mean of 0.17 ± 0.22 cm² is recorded from the abstract with the P < .01 across site types (VASO-E090), with the ROC separation statement (VASO-E104), the active-versus-normal classifier (VASO-E105) and the latent-versus-normal classifier (VASO-E107). The 'normal' sites lie in symptomatic muscle at least 5 cm from a trigger point; the standard deviation exceeds the mean, and no pain-free tissue was imaged.
Provisionally supportedconfidence: moderate · claude-fable-5-1 · run 2026-09-23-edition-015207 · unreviewed draft
Ballyns 2011 states the value directly (VASO-E090: 0.17 ± 0.22 cm², P < .01 across site types); the ROC separation (VASO-E104), the active-versus-normal classifier (VASO-E105) and the latent-versus-normal classifier (VASO-E107) support the ordering against normal sites. The 'normal' sites are palpably normal sites in symptomatic muscle, not pain-free tissue (VASO-E026 on the parent claim, disclosed).
Establishedconfidence: high · Gemini 3.8 Flash (Google) — independent check run via gemini-3.8-flash · run 2026-09-30-check-gemini-104542 · unreviewed draft
Directly confirmed by the primary text of Ballyns et al. 2011 (VASO-E090), which reports that palpably normal sites exhibited a mean trigger-point area of 0.17 ± 0.22 cm² on vibration sonoelastography, significantly smaller than both active and latent sites (P < .01, VASO-E104, VASO-E105, VASO-E107). The strongest opposing consideration is that sonoelastography was performed using an off-the-shelf massager at a single vibration frequency rather than standardized, quantitative shear-wave elastography.
Provisionally supportedconfidence: moderate · GLM 5.3 Flash (Z.ai, via Venice) — independent check run via z-ai-glm-5-3-flash · run 2026-09-30-check-glm-104542 · unreviewed draft
The normal-site value of 0.17 ± 0.22 cm² is anchored verbatim with the P < .01 comparison (E090, E104) from blinded sonographers. The strongest opposing considerations are that the standard deviation exceeds the mean, so normal-site areas overlap the trigger-point distributions substantially; sites were palpation-selected by an unblinded examiner; and the record comes from the same NIH lineage as the companion stiffness and biochemistry studies, so it is not independent replication.
Establishedconfidence: high · GPT-5.6 Sol (OpenAI) — independent check run via gpt-5.6-sol · run 2026-09-30-check-gpt-104542 · unreviewed draft
VASO-E090 directly reports the mean sonoelastographic area of palpably normal sites as 0.17 ± 0.22 cm², exactly matching the claim. The claim is limited to a descriptive value from the Ballyns study, so independent generalization is not required for its local truth. The strongest opposing consideration is that these sites were palpably normal locations within symptomatic patients, not normal tissue sampled from pain-free controls.
Well supportedconfidence: moderate · Grok 4.5 (xAI) — independent check run via grok-4.5 · run 2026-09-30-check-grok-104542 · unreviewed draft
Ballyns reports palpably normal-site mean area 0.17 ± 0.22 cm² (E090). Part of the same graded active > latent > normal ordering. Strongest opposing consideration is that “normal” sites still lie in symptomatic muscle at least 5 cm from TPs and may not represent true pain-free baseline.
Well supportedconfidence: high · Opus 5.5 (Anthropic) — independent check run via claude-opus-5-5 · run 2026-09-30-check-opus-104542 · unreviewed draft
The value is quoted verbatim from the Ballyns 2011 abstract (E090), in a study whose sonographers were blinded to clinical status. The ROC records later relinked to this claim (E104, E105, E107) concern classification and add nothing to the mean itself. It is a descriptive statistic of one study, and I rate the accuracy of its rendering, not any general norm. Strongest opposing consideration: the standard deviation exceeds the mean, implying a skewed distribution in which a minority of "palpably normal" sites carry sizeable stiff areas, and these sites were in symptomatic patients with no pain-free comparison (E026). The number therefore describes a contaminated baseline: it should not be used as a normal reference value, and it cuts against reading trigger points as sharply bounded lesions.
Provisionally supportedconfidence: moderate · claude-opus-5-5 · run 2026-09-30-edition-072251 · unreviewed draft
Palpably normal sites measured 0.17 ± 0.22 cm² (VASO-E090, VASO-E104, VASO-E105, VASO-E107), well below trigger-point sites. The normal sites lay in symptomatic muscle, and there were no pain-free controls.